+8613606716429

Installation And Maintenance Of Hydraulic Butterfly Valve

Oct 10, 2026

Installation
Valves are typically installed at the outlet of a water pump, with a recommended distance of 2 to 6 times the pipe diameter (D). During installation, pay attention to the direction of the medium flow; the sealing surface is generally positioned on the upstream side. Avoid impacts to hydraulic components during transport and lifting. Before installation, verify the parameters on the nameplate and clean the valve body and sealing surfaces. The fully open position of the butterfly valve can be adjusted using the adjustment bolts. For long-term storage, keep the valve in a cool, dry, and well-ventilated indoor area, and apply anti-rust oil to all machined surfaces.

 

Operation
Operation can be controlled via either independent (single-action) or interlocked modes. The electro-hydraulic control system is equipped with both local control circuits and remote interlocked control circuits. Local control circuits are primarily used for on-site commissioning, while remote interlocked control circuits are used for standard operation. A manual oil pump is provided for emergency operation in the event of a power failure or when no external power source is available.

 

Maintenance
Regularly check the cleanliness of the hydraulic oil and replace it as needed; typically, 20# or 30# hydraulic oil, or 46# anti-wear hydraulic oil, is used. The pre-charge nitrogen pressure in the accumulator should be tested annually. Periodically inspect pressure relays or electrical contact pressure gauges. Apply lubricant to moving mechanical parts at regular intervals (e.g., monthly). Do not make unauthorized adjustments to the hydraulic or electrical control systems during operation. Common malfunctions include leakage at the valve sealing surfaces or valve shaft, loss of system pressure, excessive noise from the oil pump, reduced pressure-holding capacity, or control system failure. Potential causes include the presence of debris or contaminants, wear, clogged oil filters, relief valve failure, or electrical component malfunctions. Depending on the specific issue, corrective actions may include cleaning, repair, component replacement, or tightening of bolts.

Send Inquiry