Stainless steel butterfly valves made of CF8M may experience corrosion during service.
Through analyses including metallographic examination, dye-penetrant testing, heat-treatment testing, and scanning electron microscopy (SEM), it has been determined that the primary cause of this corrosion is the precipitation of carbides along grain boundaries, which creates chromium-depleted zones. Specifically, chromium carbides (of the M23C6 type) precipitate along the austenite grain boundaries, depleting the surrounding areas of chromium and leading to intergranular corrosion.
Common diagnostic methods include metallographic analysis, dye-penetrant testing, heat-treatment testing, and SEM analysis. The heat-treatment process must be strictly controlled: during solution treatment, the component should be heated to a high temperature to ensure the complete dissolution of carbides, followed by rapid cooling to produce a uniform austenitic microstructure, thereby preventing carbide precipitation.